Storedge a1000 raid manager software

Excessive rdac and solaris disk driver retry attempts on io errors may result in database managers such as oracle or applications to timeout. Displaying lun specific attributes using the sun storedge tm raid manager command line for sun storedge tm a3x00 a arrays related items sun storage a3000 array. We are also able to offer sun support packages that can extend your standard warranties for your sun hardware and software. Usingsunstoredge a3x00awith sunenterprisevolumemanager. The raid manager software creates two paths to the lun in the devosadevrdsk directory. The sun storedge d array is available with cost efficient server based software raid, while the sun storedge a array has a dedicated 70 mips. Any advise on how i can probetrace this external device storedge a. Hotswappable power supplies, fan controllers, and disk drives.

Substitute the c n t x d y number from the other controller module. The systems differ primarily in their raid implementation. Raid card mylex dac960 storedge a with 3 x 18gb drives loaded. The sun storedge a array is a hardwareraid solution that offers a wide range of capabilities and.

It is designed as a raid solution for workgroup servers and contains the following. Systems with storedge a, a3x00 or a3500fc arrays, which are configured to run under volume manager software, may experience database or application problems when repeated disk io error retries occur. Quickstart reference for sun storage disk replacement. Workgroup server pci raid solutionthesunstoredge srcp. The sun storedge a3000 subsystem is a redundant array of inexpensive disks raid product. Lun 0 raid 5 346927 mb vendor id symbiosproductid storedge aproduct revision 0301boot level 03. Yes, rm6 or the command line tools in raid manager are the normal interface to the a. Ssd manager monitor drive health and usage kingston. The sun storedge a array is a hardwareraid subsystem, while the sun storedge d array is a softwareraid subsystem. Do not forget to install rm6 raid manager software to control the a. Im trying to setup two as connected to a single host w a dual port adapter. If the proper procedure is not followed, complications can arise which might lead to data loss. Sunwosar sunwosafw sunwosamn sunwosau defending upon your raid manager version and scsifibre card type you will need to patch the system.

Figure 211shows a front view of a twelve drive system. In some cases, the code name became the completed products name, but most of these code names are no longer used once the associated products are released. View online or download sun microsystems sun storedge d installation, operation and service manual, upgrade installation manual. Sun storedge a array product library documentation. If you need to download any information about our products, but the product information is not in the list, please contact our technical customer service. But i didnt install it, and configured it via telnetserial login cli. To ensure compatibility between sun storedge a3x00 a and sun enterprise volume manager, you must do the following. I think the options hardware and software flow controll are important too maybe there is an easy way to. Figure 211 sun storedge a front view of a twelve drive system. Do i need to have thesame firmware version on both controllers for the as. The sun storedge t3 array for the enterprise delivers outstanding threeway scalability of capacity, performance and availability. Oct 14, 2005 raid manager for a attached to solaris 9 or 10 server 807557 oct 14, 2005 12. Productid storedge a product revision 0301 boot level 03. The sun storedge a array is managed using the same raid manager 6 software that is used with the sun storedge a3500 arrays.

Raid manager rm6 is used to control the a array and d jbod boxen. Lun 0 raid 0 69967 mb lun 1 raid 0 69967 mb lun 2 raid 5 9934 mb lun 3 raid 5 9934 mb lun 4 raid 5 9934 mb vendor id symbios productid storedge a product revision 0301 boot level 03. Sun storedge a3500 fast delivery best prices guaranteed gss. Displaying lun specific attributes using the sun storedge. Sun enterprise 450 currently installed with sun solaris 9. The sun storedge a array is managed using raid manager 6 software. Storedge a3500a3500fc system and controller module. So the first disk on controller 1 is disk 10 and the 3rd disk on controller 2 is disk 23. The sun storedge d array is available with costefficient serverbased software raid, while the sun storedge a array has a dedicated processor managing and controlling all raid functions. This phenomenon appears on systems connected with sun storage a, a3000 and a3500 arrays, as well as sun storage 3000 arrays 3310, 3320, 3510, 3511. Does this mean i can use 12 disks to create raid 10 on storedge a. View online or download sun microsystems sun storedge a installation, operation and service manual.

The following patches are recommended for solaris 8. For a software related product documentation raid manager 6. To ensure compatibility between sun storedge a3x00a and sun enterprise volume manager, you must do the following. Included management sun storedge configuration service software software support sun storedge. Solaris pocket admin special hardware configs compnect. The storedge a3x00a and sun enterprise volume manager. Nvsram installation for upgrading and installing raid manager.

These are pretty old by now, popular during the dotbomb days circa y2k. The storedge a3x00 a and sun enterprise volume manager. The sun storedge d array is available with cost efficient server based software raid, while the sun storedge a array has a dedicated 70 mips processor managing and controlling all raid functions. I have made all the necessary changes in nf, rmparams, etc. The raid manager software allows you to reset the disk array in different raid configurations. I tried this with hp scsi box and were able to probe the external devices but for sun storedge a it was not successfull. I want to know is there anything elso i will need to do in order to preserve data. Enhanced raid manager 6 up to 15 sun storedge a arrays can be daisychained on the same ultrascsi bus up to nine in a single rack open storageultrascsi connections to microsoft windows nt systems the sun storedge d arraylowcost software raid solution the sun storedge d array does not have a hardware raid controller. Hardware and software raid implementations two subsystems are available. The controller module supports dual scsi hosts on a 16bit scsi2 bus. Sun storedge t3 array for the enterprise on queue computer. Sun storedge component manager software offers management, configuration, and health monitoring. Storedge raid manager software on sun storedge a and a3x00 systems. Managing sun storage 3000 arrays requires the sccli utility.

This software provides status and error indicators, remote system monitoring, and configuration maintenance and monitoring. I would want to ask on what software do i need to configure disk array for storedge a. Description file supported systems info version third party software licenses thirdpartylicenses. The disks are labelled on the front of the a as controller number and disk number seperated by a comma eg. The sun storedge a3x00 a subsystem in conjunction with raid manager 6 rm6 is compatible with sun enterprise volume manager 2. This software provides status and error indicators, remote system monitoring, and con. Now that it is attached, id like to know if a would support raid 10 or raid01. The sun storedge a array is a hardwareraid solution that offers a wide range of capabilities and features. Sun storedge a hardware raid controller module the sun storedge a hardware raid controller module is a compact unit designed to provide highperformance disk array management services. Following is a list of code names that have been used to identify computer hardware and software products while in development. Aa3500fcraid manager 6 rm6 for checking array health, use the raid manager 6 software, reference raid manager 6.

The sun storedge a unit is a raid controllerbased configuration. Sun microsystems sun storedge t3 configuration manual pdf. Wehn mylex scans for a new scsi device, storedge a cant be tracedprobed. The sun storedge a3x00a subsystem in conjunction with raid manager 6 rm6 is compatible with sun enterprise volume manager 2.

Displaying lun specific attributes using the sun storedgetm. Sep 23, 2019 this phenomenon appears on systems connected with sun storage a, a3000 and a3500 arrays, as well as sun storage 3000 arrays 3310, 3320, 3510, 3511. How to replace failed disk in veritas volume manager in. Raid configurations per tray jbodexpansion no controller. Raidon internal raid brochure to download msu beta for macos catalina 10. Bundled with sun storedge a3500 for dual active connection to host and automatic failover. These instructions are designed for system administrators with some working knowledge of raid manager software. For fast growing, io intensive networks, the sun storedge ad arrays provide proven performance, reliability, and versatility that will easily support your demanding storage requirements. Please let me know the step by step procedure to replace the failed disk. Read all of these release notes before attempting to install or operate the sun storedge raid manager 6. A a3500fc raid manager 6 rm6 for checking array health, use the raid manager 6 software, reference raid manager 6. Dual cooling fans hot swappable up to twelve disk drives hot swappable the raid manager controller module provides disk array management services.

309 410 395 1008 1318 593 166 475 551 686 729 1335 1445 299 1489 25 1510 511 1066 165 1146 554 752 321 1418 31 1347 1248 48 655 395